Sign In | Join Free | My burrillandco.com
Home > Coating Thickness Gauge >

Settled Fe Probe Coating Thickness Gauge Film Thickness Tester

    Buy cheap Settled Fe Probe Coating Thickness Gauge Film Thickness Tester from wholesalers
     
    Buy cheap Settled Fe Probe Coating Thickness Gauge Film Thickness Tester from wholesalers
    • Buy cheap Settled Fe Probe Coating Thickness Gauge Film Thickness Tester from wholesalers

    Settled Fe Probe Coating Thickness Gauge Film Thickness Tester

    Ask Lasest Price
    Brand Name : LEEB
    Model Number : Leeb250A
    Certification : CE, FCC EAC & ISO
    Price : Based on quantity
    Payment Terms : T/T, PayPal, Western Union, L/C
    Supply Ability : 500 sets per month
    Delivery Time : In 7-10 work days
    • Product Details
    • Company Profile

    Settled Fe Probe Coating Thickness Gauge Film Thickness Tester

    Settled Fe Probe Coating Thickness Gauge Film Thickness Tester


    Settled Fe Probe And Plastic Shell Coating Thickness Gauge With Switch off automatically or manually



    Functions & Features

    ● High quality metal probes.
    ● Two measuring methods:continuous and single;
    ● Two working mode: direct and batch;
    ● Limit setting function.
    ● Switch off automatically or manually.

    Measuring Materials
    Magnetic Induction (Fe): Measuring the thickness of Non-magnetic coating on magnetic metal substrate,
    such as aluminum, chromium, copper, zinc, rubber, paint on the base of steel, iron, alloy and magnetic
    steel


    Technical Parameters


    Technical Parameters
    Model No.Leeb250A
    Measuring principleFe
    Measuring range (µm)0~1250μm
    ProbeSettled
    ShellPlastic
    Accuracy±(1~3%H+1) μm; H refers to the thickness of testing piece
    Minimum resolution (µm)0.1μm
    Min curvature of the min area (mm)Convex1.5 Concave9
    Diameter of the min area (mm)Φ7
    Critical thickness of substrate (mm)0.5
    Memory200 groups measured data
    Dimensions115*55*23mm
    Power supplyAAA Alkaline battery
    Standard Configuration
    Main unit,5 calibration specimens (48.5μm,99.8μm,249μm,513μm 1024μm),1 probe & substrate
    Optional Accessories
    Probes,Specimens,1 leather sheath

    Troubleshooting
    The following error information table to tell you how to identify and troubleshoot:
    Error code
    Implications of error code
    The cause and solution
    E02
    Probe or instrument damageRepair probe or instrument
    E03
    Probe or instrument damage
    Repair probe or instrument
    E04
    Measured values occur large fluctuations
    (For example when soft layer measurements);
    Magnetic field effect
    When the measure menton
    the softcover, auxiliary device to
    measure should be adopted;Stay away from the
    strong magnetic field environment
    E05
    Too close to the probe from the metal substrate when the phone is switched on
    Probe from the metal substrate
    E08
    Probe or instrument damage
    Repair probe or instrument
    E11
    Probe model in conformity with this group of the original data corresponding to the probe model
    Replace the suitable probe
    Choose an unused group units
    Delete after calibration again
    E15
    Zero deviation is too big, can not be zero
    Select the appropriate substrate or repair equipment
    E20
    This set of unit for calibration value
    Choose an unused group unit Or delete after calibration again